Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 103
Filter
1.
Rev. bras. ortop ; 58(2): 240-245, Mar.-Apr. 2023. tab, graf
Article in English | LILACS | ID: biblio-1449799

ABSTRACT

Abstract Objective Tranexamic acid (TXA) is an antifibrinolytic that is widely used for decreasing blood loss and blood transfusion rates in total hip arthroplasty. However, there is limited evidence of topical TXA usage in hip hemiarthroplasty for femoral neck fractures. The present study aimed to evaluate the effects of topical TXA on blood loss and on blood transfusions in femoral neck fracture patients who underwent cemented bipolar hemiarthroplasty. Methods Twenty-six patients with femoral neck fractures who were scheduled for bipolar cemented arthroplasty were randomized into two groups. The first group of 12 patients received topical TXA during their operation, whereas 14 patients in the second group received a placebo. Hematocrit was measured at 6 and 24 hours postoperatively. Blood transfusions and postoperative complications were also recorded. Results Total blood loss was not different between the TXA group and the control group (TXA group: 459.48 ± 456.32 ml, and control group: 732.98 ± 474.02 ml; p = 0.14). However, there were no patients within the TXA group who required a blood transfusion, while there were 4 patients in the control group who received allogenic blood transfusions (p = 0.044). There were no postoperative complications, such as wound complication, venous thromboembolism, or cardiovascular complications within either group. Conclusion Topical TXA could not decrease total blood loss but was able to reduce transfusion rates in patients who underwent cemented bipolar hip hemiarthroplasty in femoral neck fractures. Further studies in doses of topical TXA in a larger sample size would be beneficial. Level of Evidence II.


Resumo Objetivo O ácido tranexâmico (TXA) é um antifibrinolítico amplamente utilizado para diminuir as taxas de perda de sangue e de transfusão de sangue na artroplastia total do quadril. No entanto, há evidências limitadas de uso tópico de TXA na hemiartroplastia do quadril para fraturas no pescoço femoral. O presente estudo teve como objetivo avaliar os efeitos do TXA tópico na perda de sangue e transfusões de sangue em pacientes com fratura femoral que foram submetidos a hemiartroplastia bipolar cimentada. Métodos Vinte e seis pacientes com fraturas no pescoço femoral e programados para artroplastia cimentada bipolar foram randomizados em dois grupos. O primeiro grupo de 12 pacientes recebeu TXA tópico durante a operação; no segundo grupo, 14 pacientes receberam placebo. O hematócrito foi medido às 6 e 24 horas no pósoperatório. Também foram registradas transfusões de sangue e complicações pósoperatórias. Resultados A perda total de sangue não foi diferente entre o grupo TXA e o grupo controle (grupo TXA: 459,48 ±456,32 ml; e grupo controle: 732,98 ±474,02 ml; p = 0,14). No entanto, não houve pacientes dentro do grupo TXA que necessitaram de transfusão de sangue, enquanto 4 pacientes no grupo controle fizeram transfusões de sangue halogênicas (p = 0,044). Não houve complicações pós-operatórias, tais como complicação da ferida, tromboembolismo venoso ou complicações cardiovasculares dentro de qualquer grupo. Conclusão O TXA tópico não conseguiu diminuir a perda total de sangue, mas foi capaz de reduzir as taxas de transfusão, em pacientes submetidos a hemiartroplastia de quadril bipolar cimentada em fraturas no pescoço femoral. Outros estudos com doses de TXA tópico em um tamanho amostral maior seriam benéficos. Nível de Evidência II.


Subject(s)
Humans , Tranexamic Acid/therapeutic use , Arthroplasty, Replacement, Hip , Femoral Neck Fractures/surgery , Hemiarthroplasty
2.
China Journal of Orthopaedics and Traumatology ; (12): 294-298, 2023.
Article in Chinese | WPRIM | ID: wpr-970866

ABSTRACT

The stability of internal fixation of femoral neck fractures can be obtained through surgical techniques, the configuration of screws and bone grafting, etc. However, the blood supply injury caused by fractures could not be completely reversed by the current medical management. Hence, the comprehensive evaluation of the residual blood supply of the femoral neck, to perioperatively avoid further iatrogenic injury, has become a hotspot. The anatomy of the extraosseous blood supply of the femoral neck has been widely reported, while its clinical application mostly involved the assessment of the medial circumflex femoral artery and retinacular arteries. However, further studies are needed to explore the prognosis of patients with these artery injuries, with different degrees, caused by femoral neck fractures. Direct observations of nutrient foramina in vivo are not possible with current clinical technologies, but it is possible to make reasonable preoperative planning to avoid subsequent femoral head necrosis based on the distribution features of nutrient foramina. The anatomy and clinical application studies of the intraosseous blood supply focused on the junction area of the femoral head and neck to probe the mechanism of femoral head necrosis. Thus, the intraosseous blood supply of other regions in the femoral neck remains to be further investigated. In addition, a blood supply evaluation system based on a three-level structure, extraosseous blood vessels, nutrient foramina, and intraosseous vascular network, could be explored to assist in the treatment of femoral neck fractures.


Subject(s)
Humans , Femur Head Necrosis , Femoral Neck Fractures/surgery , Femur Neck , Femur Head/surgery , Femoral Artery , Fracture Fixation, Internal
3.
China Journal of Orthopaedics and Traumatology ; (12): 279-283, 2023.
Article in Chinese | WPRIM | ID: wpr-970863

ABSTRACT

American Academy of Orthopaedic Surgeons (AAOS) just released the up-to-date <Management of Hip Fractures in Older Adults:Evidence-Based Clinical Practice Guideline>, which has become the principles to care hip fractures in the elderly. In comparison to the Guideline 2014, considerable changes are made in terms of guideline composition and focused items. The interval of 7 years yielded dramatic progress in the care of geriatric hip fractures, including the recommendation of cemented femoral stems in hip arthroplasty due to displaced femoral neck fractures, cephalomedullary device for unstable intertrochanteric fractures and tranexamic acid to reduce blood loss and blood transfusion. Additionally, the individualized properties of the elderly with hip fractures should be noted to balance an early operation within 24 and 48 hours and patient safety. The interpretation of <Management of Hip Fractures in Older Adults:Evidence-Based Clinical Practice Guideline> is helpful to comprehensively understand the progress of the care of geriatric hip fractures, thus to make orthopaedic surgeons master the key points of clinical practice, and to improve the quality of operations and decrease perioperative complications.


Subject(s)
Aged , Humans , Arthroplasty, Replacement, Hip , Femoral Neck Fractures/surgery , Fracture Fixation, Internal , Hip Fractures/surgery , Orthopedic Surgeons , Treatment Outcome , United States , Practice Guidelines as Topic
4.
China Journal of Orthopaedics and Traumatology ; (12): 273-278, 2023.
Article in Chinese | WPRIM | ID: wpr-970862

ABSTRACT

For patients with femoral neck fractures who plan to undergo internal fixation, satisfied alignment of fracture ends is an important prerequisite for internal fixation stability and fracture healing. There are many reports on the reduction methods of displaced femoral neck fractures, which can be summarized into three categories:First, the solely longitudinal traction of lower limbs, supplemented by other manipulations such as rotation and compression; Second, the resultant force formed by the longitudinal traction of lower limbs and the lateral traction;the third is accomplished by vertical traction in the axis of femur with hip joint flexed. Each reduction method has its own advantages, but no single method can be applied to all fracture displacement. In this paper, some classical reduction techniques in the literatures are briefly reviewed. It is hoped that clinicians will not be limited to a certain reduction method, they should analyze the injury mechanism and fracture displacement process according to the morphology features and flexibly select targeted reduction methods to improve the success rate of closed reduction of femoral neck fracture.


Subject(s)
Humans , Femoral Neck Fractures/surgery , Femur , Fracture Fixation, Internal , Fracture Healing , Traction , Treatment Outcome
5.
China Journal of Orthopaedics and Traumatology ; (12): 255-261, 2023.
Article in Chinese | WPRIM | ID: wpr-970858

ABSTRACT

OBJECTIVE@#To investigate the biomechanical characteristics of different internal fixations for Pauwels type Ⅲ femoral neck fracture with defect, and provide reference for the treatment of femoral neck fracture.@*METHODS@#Three-dimensional (3D) finite element models of femoral neck fractures were established based on CT images, including fracture and fracture with defects. Four internal fixations were simulated, namely, inverted cannulated screw(ICS), ICS combined with medial buttress plate, the femoral neck system (FNS) and FNS combined with medial buttress plate. The von Mises stress, model stiffness and fracture displacements of fracture models under 2 100 N axial loads were measured and compared.@*RESULTS@#When femoral neck fracture was fixed by ICS and FNS, the peak stress was mainly concentrated on the surface of the screw near the fracture line, and the peak stress of FNS is higher than that of ICS;When the medial buttress plate was combined, the peak stress was increased and transferred to medial buttress plate, with more obvious of ICS fixation. For the same fracture model, the stiffness of FNS was higher than that of ICS. Compared with femoral neck fracture with defects, fracture model showed higher stiffness in the same internal fixation. The use of medial buttress plate increased model stiffness, but ICS increased more than FNS. The fracture displacement of ICS model exceeded that of FNS.@*CONCLUSION@#For Pauwels type Ⅲ femoral neck fracture with defects, FNS had better biomechanical properties than ICS. ICS combined with medial buttress plate can better enhance fixation stability and non-locking plate is recommended. FNS had the capability of shear resistance and needn't combine with medial buttress plate.


Subject(s)
Humans , Femoral Neck Fractures/surgery , Fracture Fixation, Internal/methods , Bone Screws , Bone Plates , Biomechanical Phenomena , Finite Element Analysis
6.
China Journal of Orthopaedics and Traumatology ; (12): 251-255, 2023.
Article in Chinese | WPRIM | ID: wpr-970857

ABSTRACT

OBJECTIVE@#To investigate the biomechanical characteristics of retinaculum in the treatment of femoral neck fractures.@*METHODS@#The CT data of a 75-year-old female volunteer was processed by software to construct an intact femur model and femoral neck fracture model fixed with three cannulated screws, which were divided into models with retinaculum or not. The Von-Mises stress distribution and displacement were compared to analyze the stability differences between the different models to study the mechanical characteristics of the retinaculum in the treatment of femoral neck fractures.@*RESULTS@#In the intact femur, the most obvious displacement appeared in the weight-bearing area of the femoral head, with retinaculum 0.381 37 mm, and without retinaculum 0.381 68 mm. The most concentrated part of the Von-Mises stress distribution was located in the medial and inferior part of the femoral neck, with retinaculum 11.80 MPa, without retinaculum 11.91 MPa. In the femoral neck fracture fixed with three cannulated screws model, the most obvious position of displacement also appeared in the weight-bearing area of the femoral head, with retinaculum 0.457 27 mm, without retinaculum 0.458 63 mm. The most concentrated part of the Von-Mises located at the medical and inferior part of the femoral neck, with retinaculum 59.22 MPa, without retinaculum 59.14 MPa. For the cannulated screws, the Von-Mises force peaks all appeared in the posterior and superior screw, with retinaculum 107.48 MPa, without retinaculum 110.84 MPa. Among the three screws, the Von-Mises stress of the anterior-superior screw was the smallest, which was 67.88 MPa vs 68.76 MPa in the retinaculum and non-retinaculum groups, respectively.@*CONCLUSION@#The complete retinaculum has little effect on the stability of intact femur and femoral neck fractures with anatomical reduction after internal fixation, and cannot effectively improve the stability of the fracture end after the fracture.


Subject(s)
Female , Humans , Aged , Finite Element Analysis , Femoral Neck Fractures/surgery , Fracture Fixation, Internal , Bone Screws , Femur Neck , Biomechanical Phenomena
7.
China Journal of Orthopaedics and Traumatology ; (12): 232-235, 2023.
Article in Chinese | WPRIM | ID: wpr-970853

ABSTRACT

OBJECTIVE@#To analyze and compare the clinical efficacy of internal fixation and total hip replacement in the treatment of displaced femoral neck fracture from 55 to 65 years.@*METHODS@#From September 2016 to August 2020, 86 patients with Garden type Ⅲ or Ⅳ femoral neck fracture were divided into two groups according to different surgical methods. Among them, 38 patients were treated with lag screws for internal fixation, there were 26 males and 12 females, aged 55 to 64 years old with an average of(60.2±3.1) years;the other 48 patients were treated with total hip replacement, including 28 males and 20 females, aged from 57 to 65 years old with an average of(61.3±3.8) years. The time from injury to operation ranged from 1 to 3 days. The reoperation rate, incidence of deep infection, Harris score of hip joint function, visual analogue scale(VAS) of pain and patients reported outcome scores(European five-dimensional Health Questionnaire, EQ-5D) were compared between two groups.@*RESULTS@#All patients were followed up for 24 to 54 months with an average of (35.8±10.3) months. There was significant difference in reoperation rate between two groups (P<0.05). There was no significant difference on the incidence of deep infection, hip Harris score and VAS between two groups(P>0.05) . The postoperative EQ-5D score of patients with internal fixation was lower than that of total hip replacement, and the difference was statistically significant(P<0.05).@*CONCLUSION@#Both the surgery of internal fixation and total hip replacement have similar effect in short-and medium term among the patients aged 55 to 65 years old. However, for the reoperation rate, the group of internal fixation was higher than that of total hip replacement. For the subjective functional score of patients, the group of internal fixation was lower than that of total hip replacement.


Subject(s)
Male , Female , Humans , Middle Aged , Aged , Arthroplasty, Replacement, Hip/methods , Treatment Outcome , Femoral Neck Fractures/surgery , Fracture Fixation, Internal/methods , Reoperation
8.
China Journal of Orthopaedics and Traumatology ; (12): 226-231, 2023.
Article in Chinese | WPRIM | ID: wpr-970852

ABSTRACT

OBJECTIVE@#To compare the efficacy of percutaneous compression plate and cannulated compression screw in the treatment of displaced femoral neck fractures in young and middle-aged patients.@*METHODS@#From January 2015 to July 2020, 68 young and middle-aged patients with displaced femoral neck fracture were retrospectively analyzed. Among them, 31 cases were fixed by percutaneous compression plate (PCCP), and 37 cases were fixed by cannulated compression screw (CCS). General data such as gender, age, cause of injury, comorbidities, fracture classification and cause of injury of two groups were collected. The operation time, intraoperative blood loss, hospital stay, full weight bearing time, fracture healing time, visual analogue scale(VAS), Harris hip score and complications were compared between two groups.@*RESULTS@#Patients in both groups were followed up for more than 2 years. There were no significant differences in operation time, intraoperative blood loss, fracture reduction quality, hospital stay and VAS between two groups. The fracture healing time in PCCP group was significantly shorter than that in CCS group (t=-4.404, P=0.000). The complete weight bearing time of PCCP group was significantly shorter than that of CCS group (t=-9.011, P=0.000). Harris score of hip joint in PCCP group was better than that in CCS group 2 years after operation (P=0.002). Complications occurred in 3 cases (9.68%) in PCCP group, while 11 cases (29.72%) in CCS group, with a statistically significant difference (P=0.042).@*CONCLUSION@#Both PCCP and CCS can be used for the treatment of displaced femoral neck fractures in young and middle-aged people. Compared with CCS, PCCP fixation can achieve shorter fracture healing time and create conditions for early full weight bearing. PCCP results in higher hip score and lower complications.


Subject(s)
Middle Aged , Humans , Treatment Outcome , Blood Loss, Surgical , Retrospective Studies , Fracture Fixation, Internal/methods , Femoral Neck Fractures/surgery , Bone Screws
9.
China Journal of Orthopaedics and Traumatology ; (12): 221-225, 2023.
Article in Chinese | WPRIM | ID: wpr-970851

ABSTRACT

OBJECTIVE@#To investigate the clinical efficacy and advantages of Tianji orthopedic robot assisted cannulated screw internal fixation for femoral neck fracture.@*METHODS@#The clinical data of 41 patients with femoral neck fracture who underwent internal fixation with cannulated screws from January 2019 to January 2022 were retrospectively analyzed. According to different surgical methods, they were divided into Tianji robot group and traditional cannulated screw fixation group (traditional operation group). Among them, there were 18 patients in Tianji robot group including 8 males and 10 females with age of (56.00±4.22) years old, Garden typeⅠ (4 cases), type Ⅱ (11 cases), type Ⅲ (2 cases), and type Ⅳ (1 case). There were 23 patients in the traditional operation group, including 10 males and 13 females, aged (54.87±4.81) years old;there were 5 cases of Garden typeⅠ, 14 cases of type Ⅱ, 3 cases of type Ⅲ and 1 case of type Ⅳ. The operation time, intraoperative blood loss, fluoroscopy times, guide needle placement times, operation costs and other indicators were observed and compared between two groups. Harris score was used to evaluate hip joint function 12 months after operation.@*RESULTS@#The wounds of all patients healed in Grade A without complications. There were significant differences between two groups in terms of operation time, times of intraoperative fluoroscopy, times of guide needle placement, amount of intraoperative bleeding, and operation cost (P<0.05). All 41 patients were followed up for at least 12 months. The fractures of both groups were healed. There was no infection, screw loosening, fracture displacement and femoral head necrosis in Tianji robot group during follow-up;Screw loosening occurred in 2 patients in the traditional operation group during follow-up. At 12 months after operation, Harris hip joint function score of Tianji robot group was higher than that of traditional operation group in daily activity, lameness, joint activity score and total score (P<0.05).@*CONCLUSION@#Tianji robot assisted nail placement is a better method for the treatment of femoral neck fracture, which improves the surgical efficiency, is more accurate, has higher success rate of one-time nail placement, shorter operation time, less radiation, and has better hip joint function recovery after surgery.


Subject(s)
Male , Female , Humans , Middle Aged , Robotics , Retrospective Studies , Femoral Neck Fractures/surgery , Bone Screws , Fracture Fixation, Internal/methods , Treatment Outcome
10.
China Journal of Orthopaedics and Traumatology ; (12): 209-215, 2023.
Article in Chinese | WPRIM | ID: wpr-970849

ABSTRACT

OBJECTIVE@#To investigate the application of 3D printing percutaneous surgical guide plate in closed reduction and cannulated screw internal fixation of femoral neck fracture.@*METHODS@#The clinical data of 12 patients with femoral neck fracture from March 2019 to March 2022 were retrospectively analyzed. Patients were divided into observation group and control group according to different operation plans, with 6 cases in each group. The observation group received percutaneous operation guide plate assisted closed reduction and hollow screw internal fixation, while the control group received closed reduction and hollow compression screw internal fixation. The operation time, intraoperative blood loss, fluoroscopy times, and Kirschner needle puncture times were compared between two groups. The location of screws were recordedon postoperative X-ray films, follow-up time, time of complete fracture healing, Harris score of hip joint and the incidence of complications were recorded on postoperative X-ray films.@*RESULTS@#The operation time of observation group (32.17±6.18) min was shorter than that of control group (53.83±7.31) min (P<0.05). The amount of intraoperative bleeding in the observation group (18.33±2.94) ml was less than that in the control group (38.17±5.56) ml(P<0.05). The times of fluoroscopy in the observation group (7.50±1.05) were less than those in the control group (21.00±4.82) (P<0.05). The number of Kirschner needle punctures (8.00±0.63) in observation group was less than that in control group (32.67±3.08) (P<0.05). The follow-up time was(12.88±0.74) months in observation group and (12.83±0.72) months in control group, there was no significant difference between two groups (P>0.05). One year after operation, Harris score of hip joint in the observation group was(82.00±4.52) points, while that in the control group was(81.00±3.41) points, there was no significant difference between two groups(P>0.05). The time of complete fracture healing in the observation group was (7.50±1.05) months, while that in the control group was (7.67±1.21) months, there was no significant difference between two groups(P>0.05). The parallelism of the screws in the observation group was (0.50±0.11) ° and (0.76±0.15) °, which were lower than that in the control group (1.57±0.31) ° and (1.87±0.21) ° (P<0.05). The screw distribution area ratio (0.13±0.02) cm2 in the observation group was higher than that in the control group (0.08±0.01) cm2 (P<0.05). No complications such as necrosis of femoral head, nonunion of fracture, shortening of femoral neck and withdrawal of internal fixation occurred in both groups.@*CONCLUSION@#The application of 3D printing percutaneous surgical guide plate improves the accuracy and safety of closed reduction and cannulated screw internal fixation for femoral neck fracture. It has the advantages of minimally invasive, reducing radiation exposure, fast and accurate, shortening the operation time and reducing intraoperative bleeding.


Subject(s)
Humans , Retrospective Studies , Treatment Outcome , Femoral Neck Fractures/surgery , Fracture Fixation, Internal , Bone Screws , Printing, Three-Dimensional
11.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 681-687, 2023.
Article in Chinese | WPRIM | ID: wpr-981652

ABSTRACT

OBJECTIVE@#To investigate the effectiveness of joystick technique assisted closed reduction and cannulated screw fixation in the treatment of femoral neck fracture.@*METHODS@#Seventy-four patients with fresh femoral neck fractures who met the selection criteria between April 2017 and December 2018 were selected and divided into observation group (36 cases with closed reduction assisted by joystick technique) and control group (38 cases with closed manual reduction). There was no significant difference in gender, age, fracture side, cause of injury, Garden classification, Pauwels classification, time from injury to operation, and complications (except for hypertension) between the two groups ( P>0.05). The operation time, intraoperative infusion volume, complications, and femoral neck shortening were recorded and compared between the two groups. Garden reduction index was used to evaluate the effect of fracture reduction, and score of fracture reduction (SFR) was designed and was used to evaluate the subtle reduction effect of joystick technique.@*RESULTS@#The operation was successfully completed in both groups. There was no significant difference in operation time and intraoperative infusion volume between the two groups ( P>0.05). All patients were followed up 17-38 months, with an average of 27.7 months. Two patients in the observation group received joint replacement due to failure of internal fixation during the follow-up, and the other patients had fracture healing. Within 1 week after operation, the Garden reduxtion index of the observation group was better than the control group; the SFR score of the observation group was also higher than that of the control group; the proportion of femoral neck shortening within 1 week after operation and at 1 year after operation in the observation group were lower than those in the control group. The differences of the above indexes between the two groups were significant ( P<0.05).@*CONCLUSION@#The joystick technique can improve the effectiveness of closed reduction of femoral neck fractures and reduce the incidence of femoral neck shortening. The designed SFR score can directly and objectively evaluate the reduction effect of femoral neck fracture.


Subject(s)
Humans , Treatment Outcome , Bone Screws , Femoral Neck Fractures/surgery , Plastic Surgery Procedures , Fracture Fixation, Internal/methods , Retrospective Studies
12.
Rev. bras. ortop ; 57(6): 962-967, Nov.-Dec. 2022. graf
Article in English | LILACS | ID: biblio-1423638

ABSTRACT

Abstract Objective To evaluate the long-term results of valgus intertrochanteric osteotomy fixed with double angled dynamic hip screw for nonunion fracture of the neck of the femur in young adults. This implant allows more freedom of fixation in the sagittal plane. Very few studies have evaluated the long-term outcome for treatment of nonunion in fractures of the neck of the femur. Methods This is a prospective interventional study that included 20 patients with nonunion of the fracture of the neck of the femur aged < 60 years old without avascular necrosis of the head and significant resorption of the neck of the femur. A lateral closing wedge osteotomy was performed just above the lesser trochanter after inserting the Richard screw across the nonunion site, and it was fixed with a double-angle 120° barrel plate. The outcome was evaluated using union rate and the Harris Hip Score for functional outcome. Results The average postoperative decrease in the Pauwels angle was of 28.9°. A total of 80% of the cases progressed to union within a mean duration of 7.53 months. The mean Harris Hip Score at the final follow-up was 86.45. Conclusion Valgus intertrochanteric osteotomy and fixation with a double angled dynamic hip screw is a reliable and effective method for preservation of head and promoting union in an ununited fractured neck of the femur in young patients.


Resumo Objetivo Avaliar os resultados a longo prazo da osteotomia intertrocantérica valgizante, fixada com parafuso dinâmico de quadril (DHS, na sigla em inglês) de ângulo duplo, em fraturas não consolidadas do colo femoral em adultos jovens. Este implante permite uma liberdade maior de fixação no plano sagital. Muito poucos estudos avaliaram o desfecho do tratamento a longo prazo da fratura não consolidada do colo femoral. Métodos Trata-se de um estudo prospectivo de intervenção que incluiu 20 pacientes com fratura não consolidada do colo femoral com idade < 60 anos, sem necrose avascular da cabeça femoral e significativa reabsorção do colo femoral. Foi realizada uma osteotomia em cunha de fechamento lateral logo acima do trocânter menor após a inserção do parafuso tipo Richard no sítio do retardo da consolidação óssea, sendo fixada com uma placa cilíndrica de ângulo duplo de 120°. O resultado foi avaliado com o uso da taxa de consolidação e da escala Harris Hip Score quanto ao desfecho funcional. Resultados Foi obtida uma redução pós-operatória média de 28,9° do ângulo de Pauwels. Os casos que evoluíram para a consolidação alcançaram 80%, em um período médio de 7,53 meses. A média da escala Harris Hip Score foi de 86,45 no acompanhamento final. Conclusão A osteotomia intertrocantérica valgizante e a fixação com DHS de ângulo duplo é um método confiável e eficaz para a preservação da cabeça do fêmur, promovendo a consolidação de uma fratura não consolidada do colo femoral em pacientes jovens.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Osteotomy , Outcome and Process Assessment, Health Care , Femoral Neck Fractures/surgery , Femur Neck/surgery , Femur Neck/injuries , Fractures, Ununited
13.
Article in Spanish | LILACS, UY-BNMED, BNUY | ID: biblio-1383553

ABSTRACT

Las luxaciones traumáticas de cadera son poco frecuentes, y es excepcional la asociación lesional con fracturas del extremo proximal de fémur, habitualmente producidas por accidentes de alta energía. Un correcto diagnóstico, y tratamiento adecuado de la fractura, es la conducta ideal para disminuir las complicaciones. Presentamos el caso de un paciente masculino 49 años trabajador de la construcción que, en un accidente de tránsito, sufre una luxación de cadera asociado a fractura de cuello femoral, con excepcional presentación radiológica, con lesión del nervio CPE (ciático poplíteo externo), en que se realizó artroplastia total de cadera, con buena evolución y rehabilitación, retornando a su actividad laboral a los 11 meses del accidente. A propósito de este caso, realizamos una revisión bibliográfica para evaluar el tratamiento propuesto, el ideal, y pronóstico funcional de estas lesiones.


Traumatic hip dislocations are rare, and associated injuries involving fractures of the proximal end of the femur, usually as a result of high-energy accidents, are exceptional. A correct diagnosis and adequate treatment of the fracture is the most appropriate way to reduce complications. We present the case of a 49-year-old male construction worker who, as a result of a traffic accident, suffers from a hip dislocation associated with a femoral neck fracture, with exceptional radiological presentation, with injury to the EPS (External Popliteal Sciatic) nerve. Total hip arthropathy was performed, with good evolution and rehabilitation, and patient returned to work 11 months after the accident. In this particular case, we carried out a bibliographic review to evaluate the proposed treatment, the ideal treatment, and the functional prognosis of these injuries.


As luxações traumáticas do quadril são raras, e a associação de lesão com fraturas da extremidade proximal do fêmur, geralmente causada por acidentes de alta energia, é excepcional. O diagnóstico correto e o tratamento adequado da fratura é a abordagem ideal para reduzir as complicações. Apresentamos o caso de um operário da construção civil, 49 anos, que, em acidente de trânsito, sofre luxação de quadril associada a fratura do colo do fêmur, com apresentação radiológica excepcional, com lesão do nervo ciático poplíteo externo (CPE), em onde foi realizada a artroplastia total do quadril, com boa evolução e reabilitação, retornando ao trabalho 11 meses após o acidente. Em relação a este caso, realizamos uma revisão bibliográfica para avaliar o tratamento proposto, o ideal e o prognóstico funcional dessas lesões.


Subject(s)
Humans , Male , Middle Aged , Arthroplasty, Replacement, Hip , Femoral Neck Fractures/surgery , Femoral Neck Fractures/diagnostic imaging , Hip Dislocation/surgery , Hip Dislocation/diagnostic imaging , Treatment Outcome , Femoral Neck Fractures/complications , Hip Dislocation/etiology
14.
Rev. bras. ortop ; 57(3): 360-368, May-June 2022. graf
Article in English | LILACS | ID: biblio-1388023

ABSTRACT

Abstract Currently, intracapsular femoral neck fracture (IFNF) is still a great challenge for orthopedists. In spite of the progress that has been made, a high mortality rate persists in the first year, especially in Brazil, where there is no awareness that such fractures in elderly patients should be treated as amedical emergency. The present article seeks to provide an update on the preoperative, surgical, and postoperative approaches.


Resumo Atualmente, a fratura intracapsular do colo femoral (FICF) ainda é um grande desafio para os ortopedistas. Apesar dos grandes avanços feitos, persiste uma grande taxa de mortalidade no primeiro ano, sobretudo no Brasil, onde não há uma conscientização de que tais fraturas nos pacientes idosos devemser tratadas como uma urgênciamédica. O presente artigo busca fornecer uma atualização das condutas pré-operatórias, cirúrgicas e pós-operatórias.


Subject(s)
Humans , Aged , Postoperative Care , Preoperative Care , Femoral Neck Fractures/surgery , Hip Fractures/surgery , Hip Fractures/rehabilitation
15.
Chinese Journal of Medical Instrumentation ; (6): 38-41, 2022.
Article in Chinese | WPRIM | ID: wpr-928854

ABSTRACT

Cannulated Screw is a common internal fixation for the treatment of femoral neck fractures. However, the traditional implantation method has disadvantages such as inaccuracy and large radiation exposure. Based on the anatomical characteristics of the femoral neck and geometric principles, we develop a novel guide device for cannulated screws insertion. The cadaver experiment showed that it can improve the accuracy of cannulated screws implantation, reduce puncture attempts and the radiation exposure of doctors and patients.


Subject(s)
Humans , Bone Screws , Femoral Neck Fractures/surgery , Fracture Fixation, Internal , Robotic Surgical Procedures
16.
China Journal of Orthopaedics and Traumatology ; (12): 460-463, 2022.
Article in Chinese | WPRIM | ID: wpr-928341

ABSTRACT

OBJECTIVE@#To explore the incidence and risk factors of readmission of elderly patients with hip fracture after hip hemiarthroplasty.@*METHODS@#A retrospective analysis of 237 elderly hip fracture patients who underwent hip hemiarthroplasty from February 2015 to October 2020 were performed. According to the readmission status of the patients at 3 months postoperatively, the patients were divided into readmission group (39 cases)and non-readmission group(198 cases). In readmission group, there were 7 males and 32 females with an average age of(84.59±4.34) years old, respectively, there were 34 males and 164 females with average age of (84.65±4.17) years old in non-readmission group. The general information, surgical status, hip Harris score and complications of patients in two groups were included in univariate analysis, and multivariate Logistic regression was used to analyze independent risk factors of patients' readmission.@*RESULTS@#The proportion of complications(cerebral infarction and coronary heart disease) in readmission group was significantly higher than that of non-readmission group (P<0.05), and intraoperative blood loss in readmission group was significantly higher than that of non-readmission group(P<0.05). Harris score of hip joint was significantly lower than that of non-readmission group(P<0.05). The proportion of infection, delirium, joint dislocation, anemia and venous thrombosis in readmission group were significantly higher than that of non-readmission group (all P<0.05). Multivariate Logistic regression analysis showed that the risk factors for readmission of elderly patients with hip fracture after hip hemiarthroplasty included cerebral infarction, infection, delirium, dislocation, anemia and venous thrombosis (all P<0.05).@*CONCLUSION@#The complications of the elderly patients who were readmission after hip hemiarthroplasty for hip fractures were significantly higher than those who were non-readmission. Cerebral infarction, infection, delirium, dislocation, anemia and venous thrombosis are risk factors that lead to patient readmission. Corresponding intervention measures can be taken clinically based on these risk factors to reduce the incidence of patient readmissions.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Arthroplasty, Replacement, Hip , Cerebral Infarction/surgery , Delirium , Femoral Neck Fractures/surgery , Hemiarthroplasty/adverse effects , Hip Fractures/surgery , Joint Dislocations/surgery , Patient Readmission , Retrospective Studies , Risk Factors , Treatment Outcome
17.
China Journal of Orthopaedics and Traumatology ; (12): 357-360, 2022.
Article in Chinese | WPRIM | ID: wpr-928324

ABSTRACT

OBJECTIVE@#To explore feasibility of closed reduction technique under monitoring of C-arm and three screws in the fixation of abduction and insertion femoral neck fracture.@*METHODS@#Seventeen patients with abduction and insertion femoral neck fracture operated from January 2014 to December 2019 were analyzed retrospectively, including 10 males and 7 females, aged from 21 to 59(42.09±7.30) years old. According to preoperative X-ray and CT data, angle of retroversion and abduction displacement of femoral head were determined. Two 2 mm diameter Kirschner wires crossed and gently knocked into the bone of the acetabular roof from outside and front of femoral head. The proximal fracture segment was fixed on the acetabulum. Under the monitoring of C-arm, lower limb (distal fracture segment) was gradually rotated inward and retracted against direction of fracture displacement, three cannulated screws were used for internal fixation after anatomical reduction of the distal fracture end and the proximal fracture end. Garden index was evaluated, postoperative complications were observed, and Harris functional score was performed.@*RESULTS@#All 17 cases of femoral neck fracture with abduction and insertion were successfully completed closed reduction and internal fixation. The operation time was 36 to 68(43.87±7.63) min and intraoperative bleeding was 15 to 50(28.36±5.93) ml. The quality of fracture reduction was evaluated by garden index during operation. There were 12 cases of anatomical reduction, 5 cases of acceptable reduction, and no cases of unsuccessful reduction were changed to open reduction. 17 cases were followed up for 3 to 41(27.5±8.4) months. There were no complications such as femoral head necrosis, fracture nonunion, hip impingement and femoral neck shortening. MR examination showed no femoral head necrosis and articular cartilage injury. Two years after operation, Harris score of hip joint was excellent in 13 cases and good in 4 cases.@*CONCLUSION@#Closed reduction and three screws internal fixation can obtain good anatomical reduction rate and therapeutic effect in the treatment of abduction and insertion femoral neck fracture.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Bone Wires , Femoral Neck Fractures/surgery , Fracture Fixation, Internal/methods , Retrospective Studies , Treatment Outcome
18.
China Journal of Orthopaedics and Traumatology ; (12): 353-356, 2022.
Article in Chinese | WPRIM | ID: wpr-928323

ABSTRACT

OBJECTIVE@#To investigate the incidence and related risk factors of healthy side fracture after hip fracture surgery in the elderly, so as to provide basis for the prevention of re-fracture.@*METHODS@#The data of 452 patients over 65 years old with femoral neck fracture or intertrochanteric fracture treated with hip arthroplasty or proximal femoral intramedullary nailing from June 2012 to June 2017 were analyzed, including 168 males and 284 females, the age ranged from 65 to 97(75.5±7.5) years. There were 191 cases of femoral neck fracture and 261 cases of femoral intertrochanteric fracture. According to whether there was a fracture in the healthy hip after operation, the patients were divided into fracture group and no fracture group. The gender, age, body mass index, fracture type, initial treatment method, bone mineral density, bed time, medical compliance, postoperative short-term delirium, whether there were medical diseases before injury and Harris score of hip joint in the final follow-up were recorded. Univariate Logistic regression analysis was used to screen out the risk factors of healthy side fracture after operation, and then statistically significant risk factors were included in multi factor Logistic regression analysis to screen out the independent risk factors of healthy side fracture after operation of hip fracture in the elderly.@*RESULTS@#Among them, 42 of the 452 patients had hip fractures on the healthy side with an incidence of 9.3%. The average interval between the two fractures was (2.9±2.1) years. Univariate Logistic regression analysis showed that there were significant differences in age, bone mineral density, medical compliance, short-term postoperative deliriun, pre-injury complicated with medical diseases and Harris score of hip joint in the final follow-up (P<0.05). Multivariate Logistic analysis showed that age(OR=4.227), bone mineral density(OR=4.313), combined with medical diseases (OR=5.616) and low hip Harris score at the final follow-up (OR=3.891) were independent risk factors for healthy side fractures after hip fracture surgery in elderly(P<0.05).@*CONCLUSION@#The age, bone mineral density, combined with medical diseases and low Harris score of hip joint in the final follow-up are the main risk factors of healthy side fracture after hip fracture in the elderly. It is necessary to strengthen the treatment of medical diseases, anti osteoporosis and improve hip joint function within 3 years after operation, so as to prevent the occurrence of healthy side hip fracture.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Bone Density , Femoral Fractures , Femoral Neck Fractures/surgery , Femur , Hip Fractures/surgery , Risk Factors
19.
Article in Spanish | LILACS, BINACIS | ID: biblio-1353895

ABSTRACT

Las fracturas de cuello femoral son un cuadro habitual para el cirujano traumatológico y cuando se elige realizar una osteosíntesis, son muchos los factores por considerar para conseguir un buen resultado y evitar las complicaciones. En este artículo de actualización, intentamos dar 10 claves para el éxito cuando se opta por la reducción y la osteosíntesis como método terapéutico.


Femoral neck fracture is a pathology that the trauma surgeon usually faces. When he or she decides to perform osteosynthesis, there are many factors to consider in order to achieve a good result and avoid complications. In this update article we seek to offer 10 keys to success when reduction and osteosynthesis are chosen as the therapeutic method.


Subject(s)
Femoral Neck Fractures/surgery , Fracture Fixation, Internal , Hip Fractures
20.
China Journal of Orthopaedics and Traumatology ; (12): 934-940, 2021.
Article in Chinese | WPRIM | ID: wpr-921921

ABSTRACT

OBJECTIVE@#To compare the clinical efficacy of total hip arthroplasty with conventional instrument OCM approach and posterolateral approach in supine position.@*METHODS@#From February 2017 to January 2019, 67 patients underwent hip arthroplasty due to hip diseases, including 21 patients in the minimally invasive group, 12 males and 9 females;there were 10 cases of femoral neck fracture, 5 cases of aseptic necrosis of femoral head and 6 cases of hip osteoarthritis. In the traditional group, 46 cases were treated by traditional posterolateral approach, including 28 males and 18 females;there were 24 cases of femoral neck fracture, 12 cases of aseptic necrosis of femoral head and 10 cases of hip osteoarthritis. All patientsused biological ceramic artificial joint prosthesis. The operation time, intraoperative bleeding, incision length, preoperative and postoperative creatine kinase (CK-NAC), underground activity time, hospital stay, abduction angle and anteversion angle of prosthesis were observed and compared between two groups. Harris scores before operation and 12 months after operation were compared between two groups.@*RESULTS@#All cases were followed up for 14 to 26(18.4±3.6) months. There was no significant difference in intraoperative bleeding, postoperative anteversion and abduction angle between two groups (@*CONCLUSION@#The two approaches of total hip arthroplasty can obtain satisfactory results.OCM approach has less damage and rapid postoperative recovery. It is a reliable surgical approach and can be popularized and used.


Subject(s)
Female , Humans , Male , Arthroplasty, Replacement, Hip , Femoral Neck Fractures/surgery , Femur Head , Hip Prosthesis , Operative Time , Retrospective Studies , Supine Position , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL